Bartels mp6 operating manual
Also See for microComponents mp6 Series Operating manual - 32 pages. Table Of Contents. Quick Links Download this manual. Table of Contents. Previous Page. Next Page. Page 3: General Do not open the housing of the micropump and the controllers.
In those cases, Bartels Mikrotechnik cannot issue a guaranty anymore. Please keep this manual safe and give a copy to all users. Page 4: Proper Use Do not make any modifications or extensions to the pump or controller without the prior written consent of the manufacturer. Such modifications may impair the safety of the unit and are prohibited!
Bartels Mikrotechnik GmbH rejects any responsibility for damage to the unit caused by unauthorized modifications to the pump and risk and liability are automatically transferred to the operator. Page 5: Technical Specifications Technical specifications Technical Data of the mp6-hyb mp6-hyb Order code: mp6-hyb Pump type piezoelectric diaphragm pump Number of actuators 30 x 15 x 3,8 mm Dimensions without connectors 1.
Weight barbed tube clip, Fluidic connectors outer diameter 1. Page 7: Technical Specifications Mp6-Pi Technical specifications mp6-pi mp6-pi Order code: mp6-pi Pump type piezoelectric diaphragm pump Number of actuators 30 x 15 x 3,8 mm Dimensions without connectors 1.
Page 9: Technical Specifications Mp6-Pp Technical specifications mp6-pp mp6-pp Order code: mp6-pp Pump type piezoelectric diaphragm pump Number of actuators 30 x 15 x 3,8 mm Dimensions without connectors 1. Weight barbed tube clip, outer diameter MIN 1. Page Technical Specifications Mp6-Gas Technical specifications mp6-gas mp6-gas Order code: mp6-gas Pump type piezoelectric diaphragm pump Number of actuators 30 x 15 x 3,8 mm Dimensions without connectors 1.
Page Final Inspection Final inspection After production, the micropumps have to pass a final inspection. They are tested concerning the maximum flow and back pressure. Because of the mechanical fixation inside the electrical connector and due to the use of elevated driving voltages it is ensured that the pump performance is not affected by the surface corrosion.
In a long term, we will work on improving the production process. Bartels Mikrotechnik mp6 16 Rev. As a general experimental approach, we recommend a high amplitude at varying frequencies. The performance depends on the environmental conditions. Combination of micropumps The micropumps can be combined to achieve higher flow rates or pressure than the single unit can generate. Values can vary under application conditions.
Content is subject to changes without notice. Bartels Mikrotechnik mp6 5 Rev. Weight 2 g Fluidic connectors barbed tube clip, outer diameter 1. They are tested concerning the maximum flow and back pressure. Bartels Mikrotechnik mp6 9 Rev. Weight 2 g Fluidic connectors barbed tube clip, outer diameter MIN 1. Bartels Mikrotechnik mp6 3 Rev. The manual is intended to help you achieving optimal results in a short time and shall also assist avoiding possible sources of errors.
The operating manual of the controllers and the accessories are available separately. The products have been designed with state-of-the-art technology and in accordance with all relevant safety regulations. However, a risk of d … 3. Bartels Mikrotechnik mp6 14 Rev. In order to prevent damage to the flexible cable, the following points should be considered for the final pump assembly: - the flexible connector must not be bent around sharp edges or kinked - the flexible connector must not be bend on top or bottom of the pump - the Molex connector is not water tight, additional sealing with e.
For the delivery of gases, please read the section to mp6-gas.
0コメント